Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add filters








Language
Year range
1.
Chinese Journal of Experimental Ophthalmology ; (12): 266-270, 2023.
Article in Chinese | WPRIM | ID: wpr-990841

ABSTRACT

Objective:To identify the risk factors for simple congenital ptosis.Methods:A case-control study was performed.A total of 106 children diagnosed with simple congenital ptosis at the Second Affiliated Hospital of Zhejiang University School of Medicine from October 2018 to January 2021 were recruited as a case group, and 106 sex-matched children without congenital abnormalities were enrolled as a control group at the same period.Ophthalmic examinations, including interpalpebral fissure height and margin reex distance 1, were performed on all participants.A questionnaire survey was administered to their mothers.The questionnaire included demographic information, prenatal maternal diseases, medical treatments and environmental exposures during pregnancy.Univariate analysis was used to compare the differences in variables between the case and control groups.Variables with P<0.20 were retained for multivariate logistic regression analysis to identify the risk factors for simple congenital ptosis.The goodness of fit of the model was evaluated by the Hosmer-Lemeshow test, and collinearity was assessed by the variance inflation factor (VIF). This study adhered to the Declaration of Helsinki.The study protocol was approved by the Ethics Committee of the Second Affiliated Hospital of Zhejiang University School of Medicine (No.2019-136). The method and purpose of the study were fully explained to the children's guardians and written informed consent was obtained. Results:Comparisons of gestational age <37 weeks, birth order ≥2, maternal age, antibiotic use in the first trimester, paternal smoking ≥half a pack per day, and prenatal maternal passive smoking between the two groups were all with P<0.20.Multivariate logistic regression analysis showed that gestational age <37 weeks (odds ratio [ OR]=4.58; 95% confidence interval [ CI]: 1.24-16.85), paternal smoking ≥half a pack per day ( OR=2.28; 95% CI: 1.22-4.28) and prenatal maternal passive smoking ( OR=3.13; 95% CI: 1.16-8.41) were risk factors for simple congenital ptosis.No significant collinearity was found among these identified factors (all VIF<5). Conclusions:Preterm birth, paternal smoking, and prenatal maternal passive smoking are risk factors for simple congenital ptosis.

2.
Journal of Environmental and Occupational Medicine ; (12): 1079-1084, 2023.
Article in Chinese | WPRIM | ID: wpr-988753

ABSTRACT

Background Diacetyl (DC) is widely used in the food flavoring industry and excessive occupational exposure to DC can cause serious respiratory diseases. However, there is no corresponding national standard method for the determination of DC in the air of workplace. Objective To establish a method for the determination of DC in workplace air by high performance liquid chromatography using 4-nitro-o-phenylenediamine (NPDA) as precolumn derivatization. Methods DC in the air of workplace was collected by solution absorption method. This experiment used NPDA as the derivatization reagent. By adjusting acidity of solution and optimizing concentration ration of DC/NPDA, derivatization temperature, and time, a method for the determination of DC in workplace air was proposed, and its performance indexes such as linearity, detection limit, and lower limit of quantification were obtained. Sampling efficiency was evaluated by relative comparison method, and sample stability was evaluated by sample preservation test. Accuracy and precision of the method were evaluated by standard addition recovery test with blank samples, and an interference test was carried out by adding standard samples. The established method was applied to actual samples to evaluate its adaptability. Results A combination of 60 °C for 2 h was selected for derivatization because a higher derivatization reaction temperature and a longer reaction time associated with a higher derivatization efficiency. The solution was separated by SB-C18 column (250 mm×4.6 mm, 5 μm) at 30 ℃, using a mixture of methanol and water (v/v, 65%/35%) as mobile phase with an elution flow rate of 1.0 mL·min−1, and was detected with a variable wavelength detector (λmax=257 nm) by qualitative analysis based on retention time and quantitative analysis based on external standard method. In terms of the proposed method, the linear range of detection was from 5 μg·L−1 to 2000 μg·L−1, with a correlation coefficient of 0.9999, and a detection limit of 1.3 μg·L−1, the quantitative detection of the lower limit was 4.3 μg·L−1, with a sampling volume V0 of 3.0 L, the minimum detection concentration was 4.3 μg·m−3, and the minimum quantitative concentration was 14.3 μg·m−3. The recovery rate was 99.1%-100.8%, the intra-batch precision was 0.5%-3.0%, and the inter-batch precision was 1.2%-2.0%. The average sampling efficiency of this method was 94.5%, and the sample could be stored at 4 °C for at least 14 d. The coexisting components in the air of the workplace did not interfere with the determination of DC. The DC content in the air of a flavor workplace was 5.86-8.85 mg·m−3. Conclusion A determination method for DC in workplace air by high performance liquid chromatography using NPDA as precolumn derivatization after being collected by 1.0% phosphoric acid absorbent is proposed and has the advantages of simple operation, high sensitivity, and good accuracy. With no DC loss and degradation, the method may satisfy the request for DC determination in the air of workplace.

3.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 347-353, 2022.
Article in Chinese | WPRIM | ID: wpr-935808

ABSTRACT

Objective: To quantitatively evaluate the content differences of trace elements in workers with occupational exposure to lead. Methods: In January 2021, relevant literatures on the contents of trace elements in workers with occupational exposure to lead published from 1990 to 2020 were searched through CNKI, Wanfang, VIP, PubMed, web of science and Embase. Screened and extracted the literatures, and evaluated the quality of the included literatures with Newcastle Ottawa Scale. Meta analysis was performed with Review Manager 5.3 software, and standardized mean difference (SMD) and its 95% confidence interval were used as effect indicators. Results: A total of 20 literatures were included, and the quality scores were 5-7. The results of Meta-analysis showed that compared with the control group, the contents of blood zinc (SMD=-1.01, 95%CI: -1.53, -0.49) , hair zinc (SMD=-0.17, 95%CI: -0.33, -0.01) , hair copper (SMD=-0.50, 95%CI: -1.01, 0) , hair iron (SMD=-3.91, 95%CI: -5.80, -2.03) and hair manganese (SMD=-1.09, 95%CI: -2.02, -0.15) in occupational lead exposure group were significantly lower (P<0.05) . Compared with the control group, the content of cobalt in hair of occupational lead exposure group (SMD=1.41, 95%CI: 0.72, 2.10) was higher, and the difference was statistically significant (P<0.05) . There was no significant difference in the contents of blood chromium, blood copper, blood iron, blood manganese, blood selenium and hair nickel between the two groups (P>0.05) . Conclusion: Workers with occupational exposure to lead have abnormal trace elements.


Subject(s)
Humans , Copper , Iron , Lead , Manganese , Occupational Exposure , Trace Elements , Zinc
4.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 65-68, 2022.
Article in Chinese | WPRIM | ID: wpr-935746

ABSTRACT

Objective: To establish a method for the determination of methyl isobutyl ketone (MIBK) in urine samples by headspace-gas chromatography-mass spectrometry. Methods: Automatic headspace sampling technique was adopted to optimize the headspace conditions (headspace bottle heating temperature and equilibration time) and gas chromatographic conditions. A total of 5 ml samples were taken and added with 3.0 g ammonium sulfate into a 20 ml headspace bottle. After heated at 60 ℃ for 30 mins, gas from the upper part of headspace bottle was injected into gas chromatography with an injection volume of 100 μl. The target was separated by HP-5MS UI (30 m×0.25 mm×0.25 μm) capillary column and then detected by mass spectrometry detector. The retention time and external standard method were used for qualitative and quantitative analysis of MIBK in samples, respectively. Results: The standard curve of MIBK showed significant linearity between 20.0-1 000.0 μg/L. The standard curve was y=62.9x-652.5, and the correlation coefficient r=0.9998. The detection limit of MIBK was 5.0 μg/L and the quantification limit of MIBK was 16.0 μg/L. The average recovery rate was 95.3%~100.2% at three spiked concentrations of low (50.0 μg/L) , medium (200.0 μg/L) and high (500.0 μg/L) . The intra-day and inter-day precisions were 1.7%~3.8% (n=6) and 1.2%~4.0% (n=6) respectively. This method was stable for the determination of MIBK, and the urine could be kept 14 d at -20 ℃ without significantly loss. Conclusion: This method is proved to be simple, practical and highly sensitive. It can satisfy the request for the determination of urine samples of workers exposed to MIBK.


Subject(s)
Humans , Gas Chromatography-Mass Spectrometry , Methyl n-Butyl Ketone
5.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 463-465, 2018.
Article in Chinese | WPRIM | ID: wpr-806622

ABSTRACT

Objective@#To establish a method for determination the S-phenylmercapturic acid in urine by dispersive solid-phase extraction using Humic Acid/Fe3O4 magnetic nanocomposite as adsorbent.@*Methods@#The 5 ml of urine samples were adjusted to pH 1.0 and extracted by Fe3O4@HA. Then the analytes were separated on EC-C18 capillary column and detected by HPLC-VWD. The S-phenylmercapturic acid was characterized by the retention time and quantified by peak area and external standard method.@*Results@#The standard curves of SPMA showed significant linearity between 0.04~1.00 mg/L (r=0.999 7) . The average recovery was 94.2%~102.4%. The intra-day and inter-day precisions (RSD) were 2.9~6.7% (n=6) and 3.1~7.5% (n=6) respectively. The detect limit of SPMA was 0.012 g/L (S/N=3) .@*Conclusion@#This method is simple, rapid, sensitive and accurate. It is applicable for determination of SPMA in the urine of works who were exposed to benzene.

6.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 780-782, 2017.
Article in Chinese | WPRIM | ID: wpr-809354

ABSTRACT

Objective@#To establish a method for determing the trichloroethylene(TCE)and trichloroethanol(TCOH)in blood samples by liquid-liquid extraction-gas chromatography with electron capture detector.@*Methods@#With this method,ether was used as extraction solvent and trichloromethane was used as an internal standard. The whole blood sample was extracted with ether, and dehydrated by anhydrous sodium sulfate. Then the analytes were separated on HP-5 capillary column(30m×0.32mm×0.15μm)and detected byECD.The retention time was for qualitative analysis and the internal standard was for quantitation.@*Results@#The standard curves of TCE and TCOH showed significant linearity between 95.5μg/L-7640.0μg/L(r=0.9997)and 19.0μg/L-1520.0μg/L(r=0.9992). The average recovery was 95.5%-103.6%.The intra-day and inter-day precisions(RSD)were 2.5%-6.8%(n=6)and 1.6%-4.3%(n=6) respectively. The detect limit of TCE and TCOH were 2.10 μg/L and 0.56μg/L(S/N=3)respectively.The blood can be kept 7 days at-20℃ refrigerator without significantly loss.@*Conclusion@#This method is proved to be simple,practical and highly sensitive. It can satisfy the request for the determination of blood samples of humans exposed to TCE.

SELECTION OF CITATIONS
SEARCH DETAIL